Menu
Your Cart

60W 9.99A 30V Constant Current Electronic Load / Dummy Load/ Aging Battery Capacity Tester - ZPB30A1

60W 9.99A 30V Constant Current Electronic Load / Dummy Load/  Aging Battery Capacity Tester - ZPB30A1
60W 9.99A 30V Constant Current Electronic Load / Dummy Load/  Aging Battery Capacity Tester - ZPB30A1
60W 9.99A 30V Constant Current Electronic Load / Dummy Load/  Aging Battery Capacity Tester - ZPB30A1
60W 9.99A 30V Constant Current Electronic Load / Dummy Load/  Aging Battery Capacity Tester - ZPB30A1
60W 9.99A 30V Constant Current Electronic Load / Dummy Load/  Aging Battery Capacity Tester - ZPB30A1
60W 9.99A 30V Constant Current Electronic Load / Dummy Load/  Aging Battery Capacity Tester - ZPB30A1
Generic
60W 9.99A 30V Constant Current Electronic Load / Dummy Load/ Aging Battery Capacity Tester - ZPB30A1
₹​2,449.00
₹​2,075.42 + 18% GST
All Inclusive, Shipping Calculated at Checkout

B2B GST Credit Available

60W Electronic DC Load Max 30V 9.99A - Constant Current - Battery Capacity Tester Mode - ZPB30A1


A stable and time tested design of 60W DC electronic load. It works in two different modes. In the first mode it acts as a constant current sinking load with both voltage and current to be set byy the user. In the second mode it can be used as a battery capacity tester.

  • constant current mode
  • max voltage: 30V
  • discharge current: 0.2A to 9.99A (+/- 0.7% + 1 digit)
  • max dissipated power: 60W
  • voltage measurement error: 1% + 2 digits

Simple and versatile electronic load. Automatic memory function with all parameters, is well suited for automated assembly of the power adapter aging cabinet. Power supply requirement: DC12V voltage (actual voltage 11-14V) current is not less than 0.5A of power, the power will be displayed inappropriate " Err6"


Features : 

  • Operating modes: single mode constant current (CC)
  • Discharge current: 0.20-9.99A stepper 0.1A or0.01A
  • Discharge current maximum error: 0.7% +-0.01A
  • The maximum capacity test error: 0.5A 2.5%, 2A 1.5%, 5A and above 1.2%
  • Offline (termination) Voltage Range: 1.0-25.0V stepping 1V or 0.1V
  • Discharge voltage: 1.00-30.00V
  • The maximum voltage measurement error: 1% + - 0.02V
  • Maximum power: 60W super power automatically limits the maximum current (for example, up to 60W when it can open 9.99A 6V and 20V maximum at the only open 3.00A)

Error Codes

  • Err1: ultra-high capacity test the battery voltage.
  • Err2: battery voltage is below the set termination voltage is not connected to the battery or the battery is reversed.
  • Err3: line resistance is too large or the battery can not afford to set the discharge current.
  • Err4: circuit failure.
  • Err6: working power is inappropriate, use a standard 12V power supply, and the supply current is not less than 0.5A.
  • otP: overheating protection.
  • Ert: temperature sensor failure or the temperature is too low.
  • ouP: ultra-high voltage electron -load mode .
  • oPP: under ultra-high power electronic load mode instantly.  


Write a review

Note: HTML is not translated!
Bad Good
Captcha